Mini Air Quality Monitoring System
Product Details
Application Scenarios
Widely used for regional, boundary, and large-scale environmental monitoring in sectors such as environmental protection, forestry, and industry.
How it works
The micro air quality monitoring system measures PM2.5, PM10, carbon monoxide, sulfur dioxide, nitrogen dioxide, ozone, VOCs, temperature, humidity, atmospheric pressure, wind speed, wind direction, and more. Monitoring parameters can be customized to meet specific user needs. The sensors utilize high-quality imported core components: gas sensors employ high-precision four-electrode electrochemical and PID technologies; particulate matter sensors use light scattering methods. All core components are original imported products, ensuring fast response times, high reliability, low maintenance costs, and a long service life. The platform's data center provides real-time visualization and monitoring of air quality across all monitoring points in the designated area. It supports online data queries, report generation, data aggregation and ranking, as well as air quality alerts and forecasts.
Key Features
(Measures 1 SO2, NO2, O3, CO, PM10, PM2.5, temperature, humidity, wind speed, wind direction, atmospheric pressure, and more;)
Compact and lightweight (2); easy to install and maintain on-site, enabling rapid point relocation.
(3) features GPS positioning and 4G wireless data transmission.
(4) features automatic alerting for data exceedance or anomalies;
(5) provides device information management, data management, and data quality control capabilities.
(6) supports both municipal power and solar power modes, ensuring continuous system operation for over 6 hours after external power failure.
Modular design for gas and particulate matter detection in (7) for easy maintenance.
(8) supports remote calibration (automatic calibration via remote terminal) and data resume transmission after power loss.
Key Technical Specifications
Measurement Factor | PM10, PM2.5 | |
Particulate Matter Detection Module | Measurement Principle | Light Scattering Method |
Measurement Range | PM2.5: 5~0 PM10: 1mg/m3~0 | |
Parallelism | PM2.5: ≤7% PM10 : ≤5% | |
Gas Pollutant Detection Module | Measurement Principle | Electrochemical Method |
Measurement Range | SO₂, NO₂, O₃: 0~500ppb; CO: 0~5 ppm | |
Indication Error | ≤±4%F.S. | |
Repetitiveness | ≤2% | |
Stability | ≤±3% | |
Meteorological Parameters | Temperature | Measurement range: -40 to +85°C, accuracy: ±1°C; |
Humidity | Measurement range: 0 to 100%RH, accuracy ±3%RH | |
Wind Speed | Measurement range: 0–70 m/s, accuracy: ±0.3m/s | |
Wind Direction | Measurement range 0° to 360°, accuracy ±3° | |
Atmospheric pressure | Measurement Range500-1100 hPaaccuracy±0.3hpa | |
Others | Communication Method | 2G/3G/4G/ Network Port |
Location feature | GPS Location | |